In this work, the author presents a novel wireless robotic capsule endoscope for GI tract examination, which uses a magnet based localization and orientation system. Here, the capsule encloses a permanent magnet, and moves in a patient’s GI tract. Its magnetic intensities in a number of spatial positions are measured by magnetic sensor around the patient’s body. The author derived its magnetic intensities as nonlinear functions of magnet’s 3D position and 2D orientation parameters, which can be solved by minimizing an objective error function using a nonlinear optimization algorithm. Further, a linear algorithm was proposed and its execution efficiency is significantly improved. Based on the proposed localization algorithm, a real time computer localization system was built with 16 Honeywell 3-axis AMR sensors. The experimental results show that the average localization error is about 3.3 mm and an orientation error about 3.0º. Because the magnet’s orientation misses the information of capsule’s rotation along its own central axis, a supplemental method is proposed by an imaging technique. Applying an 8-point algorithm on the endoscopic images, the 3D rotation and 2D transition parameters of the endoscope are solved, while the 3D rotation can be further decomposed into two sub-rotations, the rotation of the camera’s central axis and the rotation around this axis. Therefore, 3D localization and 3D orientation parameters are obtained by this integration of the magnetic and imaging methods. This proposed method and system is most suitable for capsule endoscope because it is not only of high localization accuracy but free of the power supply and relative circuitry.
This book will be of good references for the researchers and doctors in the areas of capsule endoscopy, medical surgery navigation, biomedical MEMS equipment, magnetic tracking technique, and micro-robot localization.
Verfügbare Online-Dokumente zu diesem Titel
Sie benötigen den Adobe Reader, um diese Dateien ansehen zu können. Hier erhalten Sie eine kleine Hilfe und Informationen, zum Download der PDF-Dateien.
Bitte beachten Sie, dass die Online-Dokumente nicht ausdruckbar und nicht editierbar sind.
Bitte beachten Sie auch weitere Informationen unter: Hilfe und Informationen.
 
 DokumentGesamtdokument 
 DateiartPDF 
 Kosten36,60 € 
 AktionDownloadZahlungspflichtig kaufen und download der Datei 
     
 
 DokumentInhaltsverzeichnis 
 DateiartPDF 
 Kostenfrei 
 AktionDownloadDownload der Datei 
     
Benutzereinstellungen für registrierte Online-Kunden (Online-Dokumente)
Sie können hier Ihre Adressdaten ändern sowie bereits georderte Dokumente erneut aufrufen.
Benutzer
Nicht angemeldet
Teilen
Shaker Verlag GmbH
Am Langen Graben 15a
52353 Düren
  +49 2421 99011 9
Mo. - Do. 8:00 Uhr bis 16:00 Uhr
Fr. 8:00 Uhr bis 15:00 Uhr
Kontaktieren Sie uns. Wir helfen Ihnen gerne weiter.
Captcha
Social Media